Lightolier inomhusinredning 0790 Manual

PDF-manualer
1 Sidor Engelska

Lightolier inomhusinredning 0790
Sidor
AV
1
1
FRAME-IN KIT (FIK) INSTALLATION: See Frame-In Kit Instruction Sheet for installation procedure.
2 INSTALLATION OF TRIM IN FIK’S WITH ROTO-CLIPS:
A. Rotate (3) Roto-clips so that the short legs extend inwardly toward center opening.
B. Remove lens holder assembly from trim by pulling lens holder assembly away from housing then
squeezing Torsiontite springs together and removing from slots in housing.
C. Insert FIK socket cup into neck of trim making sure springs of socket cup snap into the slots of trim.
D. Push trim straight up until it is tight against ceiling.
E. Reinstall lens holder assembly by squeezing Torsiontite springs and inserting through housing slots.
F. NOTE: To remove trim from ceiling, first remove lens holder assembly as in Step B above, then turn
trim counterclockwise while pulling downward.
Figure A
Figure B
Figure C
Figure D
Figure E
3 PREPARATION OF SOCKET CUP ON FIK’s WITH LAMP ADJUSTMENT MECHANISM:
A. Locate the 3 tabs that retain the lamp adjustment mechanism to the socket cup. See figure F below.
B. With a small flat blade screwdriver, bend the tabs outward so they are flush with the socket cup wall.
C. Remove adjustment mechanism and discard. See figure G below.
D. Attach lamp to socket. See figure H below.
E. Mount lamp in holder provided in trim. See figure I below.
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To
assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electric shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
INSTALLATION PROCEDURE FOR: 2090, 2090LV
2090 for use with 200IC/AIC, 2002P1 and 2003R only.
2090LV for use with 2000AICV/LV/LVR/LVNT and2004ICV only.
CAUTION: USE ONLY REFLECTOR TRIMS PROVIDED BY LIGHTOLIER. USE OF OTHER MANUFACTURER’S REFLECTOR
TRIMS MAY VOID THE UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD.
INSTRUCTION SHEET NO.
IS:2090
A0605
Page 1 of 1
CAUTION: BEFORE INSTALLING REFLECTOR TO FRAME-IN-KIT, READ MARKINGS IN REFLECTOR AND IN SOCKET CUP
OF FRAME-IN-KIT TO DETERMINE LAMP WATTAGE AND TYPE APPLICABLE FOR YOUR INSTALLATION.
CAUTION: (RISK OF FIRE) FOR NON-IC RATED INSTALLATIONS, DO NOT INSTALL INSULATION ABOVE
OR WITHIN 3 INCHES OF ANY PART OF FIXTURE.
A COMPANY
631 Airport Road, Fall River, MA 02720
Relaterade manualer för Lightolier inomhusinredning 0790